Provider: NIHR Journals Library Content:text/plain; charset="UTF-8" TY - RPRT LB - 1. AU - Committee on Medical Aspects of Radiation in the Environment (COMARE) TI - Sixteenth Report. Patient Radiation Dose Issues Resulting from the Use of CT in the UK CY - London PB - Public Health England PY - 2014 ER - TY - JOUR LB - 2. AU - Ehrmann, S AU - Aronson, D AU - Hinson, JS TI - Contrast-associated acute kidney injury is a myth: yes J2 - Intensive Care Med PY - 2018 VL - 44 SP - 104 EP - 106 UR - https://doi.org/10.1007/s00134-017-4950-6 ER - TY - JOUR LB - 3. AU - Weisbord, SD AU - du Cheryon, D TI - Contrast-associated acute kidney injury is a myth: No J2 - Intensive Care Med PY - 2018 VL - 44 SP - 107 EP - 109 UR - https://doi.org/10.1007/s00134-017-5015-6 ER - TY - JOUR LB - 4. AU - Kashani, K AU - Levin, A AU - Schetz, M TI - Contrast-associated acute kidney injury is a myth: we are not sure J2 - Intensive Care Med PY - 2018 VL - 44 SP - 110 EP - 114 UR - https://doi.org/10.1007/s00134-017-4970-2 ER - TY - JOUR LB - 5. AU - McDonald, RJ AU - McDonald, JS AU - Newhouse, JH AU - Davenport, MS TI - Controversies in contrast material-induced acute kidney injury: closing in on the truth? J2 - Radiology PY - 2015 VL - 277 SP - 627 EP - 632 UR - https://doi.org/10.1148/radiol.2015151486 ER - TY - GEN LB - 6. AU - ACR Committee on Drugs and Contrast Media TI - ACR Manual on Contrast Media: Version 10.3 2018 CY - Reston, VA PB - American College of Radiology PY - 2018 ER - TY - JOUR LB - 7. AU - Levey, AS AU - Stevens, LA AU - Schmid, CH AU - Zhang, YL AU - Castro, AF AU - Feldman, HI TI - A new equation to estimate glomerular filtration rate J2 - Ann Intern Med PY - 2009 VL - 150 SP - 604 EP - 612 UR - https://doi.org/10.7326/0003-4819-150-9-200905050-00006 ER - TY - JOUR LB - 8. AU - Levey, AS AU - Bosch, JP AU - Lewis, JB AU - Greene, T AU - Rogers, N AU - Roth, D TI - A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of Diet in Renal Disease Study Group J2 - Ann Intern Med PY - 1999 VL - 130 SP - 461 EP - 470 UR - https://doi.org/10.7326/0003-4819-130-6-199903160-00002 ER - TY - JOUR LB - 9. AU - Vanommeslaeghe, F AU - De Mulder, E AU - Van de Bruaene, C AU - Van de Bruaene, L AU - Lameire, N AU - Van Biesen, W TI - Selecting a strategy for prevention of contrast-induced nephropathy in clinical practice: an evaluation of different clinical practice guidelines using the AGREE tool J2 - Nephrol Dial Transplant PY - 2015 VL - 30 SP - 1300 EP - 1306 UR - https://doi.org/10.1093/ndt/gfv220 ER - TY - GEN LB - 10. AU - European Society of Urogenital Radiology (ESUR) TI - ESUR Guidelines on Contrast Agents v10.0 PB - ESUR PY - 2018 UR - https://www.esur-cm.org/ Y2 - 28 February 2019 ER - TY - GEN LB - 11. AU - The Royal Australian and New Zealand College of Radiologists TI - Iodinated Contrast Media Guideline V2.3 CY - Sydney, NSW PB - The Royal Australian and New Zealand College of Radiologists PY - 2018 ER - TY - JOUR LB - 12. AU - Harris, MA AU - Snaith, B AU - Clarke, R TI - Strategies for assessing renal function prior to outpatient contrast-enhanced CT: a UK survey J2 - Br J Radiol PY - 2016 VL - 89 SP - 20160077 UR - https://doi.org/10.1259/bjr.20160077 ER - TY - JOUR LB - 13. AU - Cope, LH AU - Drinkwater, KJ AU - Howlett, DC TI - RCR audit of compliance with UK guidelines for the prevention and detection of acute kidney injury in adult patients undergoing iodinated contrast media injections for CT J2 - Clin Radiol PY - 2017 VL - 72 SP - 1047 EP - 1052 UR - https://doi.org/10.1016/j.crad.2017.07.002 ER - TY - JOUR LB - 14. AU - Azzouz, M AU - Romsing, J AU - Thomsen, HS TI - Can a structured questionnaire identify patients with reduced renal function? J2 - Eur Radiol PY - 2014 VL - 24 SP - 780 EP - 784 UR - https://doi.org/10.1007/s00330-013-3065-x ER - TY - BOOK LB - 15. AU - Gbinigie, O AU - Thompson, M AU - Price, CP AU - Heneghan, C AU - Plüddemann, A TI - Point-of-Care Creatinine Testing for the Detection and Monitoring of Chronic Kidney Disease CY - Oxford PB - NIHR Diagnostic Evidence Co-operative Oxford PY - 2014 ER - TY - JOUR LB - 16. AU - McFadden, EC AU - Hirst, JA AU - Verbakel, JY AU - McLellan, JH AU - Hobbs, FDR AU - Stevens, RJ TI - Systematic review and metaanalysis comparing the bias and accuracy of the modification of diet in renal disease and chronic kidney disease epidemiology collaboration equations in community-based populations J2 - Clin Chem PY - 2018 VL - 64 SP - 475 EP - 485 UR - https://doi.org/10.1373/clinchem.2017.276683 ER - TY - GEN LB - 17. AU - Abbott TI - i-STAT Alinity CY - Princeton, NJ PB - Abbott Point of Care Inc. PY - 2019 UR - www.pointofcare.abbott/int/en/offerings/istat-alinity Y2 - 20 March 2019 ER - TY - JOUR LB - 18. AU - Bland, JM AU - Altman, DG TI - Statistical methods for assessing agreement between two methods of clinical measurement J2 - Lancet PY - 1986 VL - 1 SP - 307 EP - 310 UR - https://doi.org/10.1016/S0140-6736(86)90837-8 ER - TY - JOUR LB - 19. AU - Kidney Disease: Improving Global Outcomes (KDIGO) TI - KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease J2 - Kidney Int Suppl PY - 2013 VL - 3 SP - 1 EP - 150 ER - TY - GEN LB - 20. AU - National Institute for Health and Care Excellence (NICE) TI - Chronic Kidney Disease in Adults: Assessment and Management. Clinical Guideline [CG182] CY - London PB - NICE PY - 2014 UR - www.nice.org.uk/guidance/cg182/chapter/1-Recommendations Y2 - 21 May 2019 ER - TY - BOOK LB - 21. AU - Lunn, D AU - Jackson, C AU - Best, N AU - Thomas, A AU - Spiegelhalter, D TI - The BUGS Book CY - Boca Raton, FL PB - CRC Press PY - 2013 UR - https://doi.org/10.1201/b13613 ER - TY - JOUR LB - 22. AU - Lunn, D AU - Spiegelhalter, D AU - Thomas, A AU - Best, N TI - The BUGS project: evolution, critique and future directions J2 - Stat Med PY - 2009 VL - 28 SP - 3049 EP - 3067 UR - https://doi.org/10.1002/sim.3680 ER - TY - BOOK LB - 23. AU - Gelman, A AU - Carlin, JB AU - Stern, HS AU - Dunson, DB AU - Vehtari, A AU - Rubin, DB TI - Bayesian Data Analysis CY - London PB - Chapman & Hall PY - 2014 UR - https://doi.org/10.1201/b16018 ER - TY - JOUR LB - 24. AU - Jackson, CH TI - Displaying uncertainty with shading J2 - Am Stat PY - 2008 VL - 62 SP - 340 EP - 347 UR - https://doi.org/10.1198/000313008X370843 ER - TY - JOUR LB - 25. AU - Brooks, SP AU - Gelman, A TI - General methods for monitoring convergence of iterative simulations J2 - J Comput Graph Stat PY - 1998 VL - 7 SP - 434 EP - 455 UR - https://doi.org/10.1080/10618600.1998.10474787 ER - TY - JOUR LB - 26. AU - Gelman, A AU - Rubin, DB TI - Inference from iterative simulation using multiple sequences J2 - Stat Sci PY - 1992 VL - 7 SP - 457 EP - 472 UR - https://doi.org/10.1214/ss/1177011136 ER - TY - JOUR LB - 27. AU - Botz, C AU - Sorenson, L AU - Karon, B TI - Comparison of whole blood and serum creatinine and estimated glomerular filtration rate for screening of at-risk patients prior to radiographic procedures J2 - Clin Chem PY - 2013 VL - 1 SP - A192 ER - TY - JOUR LB - 28. AU - Dorward, J AU - Yende-Zuma, N AU - Samsunder, N AU - Karim, QA AU - Drain, PK AU - Garrett, N TI - Clinic-based evaluation of a point-of-care creatinine assay to screen for renal impairment among HIV-positive patients receiving tenofovir disoproxil fumarate J2 - J Acquir Immune Defic Syndr PY - 2018 VL - 77 SP - e36 EP - e39 UR - https://doi.org/10.1097/QAI.0000000000001613 ER - TY - JOUR LB - 29. AU - Houben, IPL AU - van Berlo, CJLY AU - Bekers, O AU - Nijssen, EC AU - Lobbes, MBI AU - Wildberger, JE TI - Assessing the risk of contrast-induced nephropathy using a finger stick analysis in recalls from breast screening: the CINFIBS Explorative Study J2 - Contrast Media Mol Imaging PY - 2017 VL - 2017 SP - 5670384 UR - https://doi.org/10.1155/2017/5670384 ER - TY - JOUR LB - 30. AU - Inoue, A AU - Nitta, N AU - Ohta, S AU - Imoto, K AU - Yamasaki, M AU - Ikeda, M AU - Murata, K TI - StatSensor-i point-of-care creatinine analyzer may identify patients at high-risk of contrast-induced nephropathy J2 - Exp Ther Med PY - 2017 VL - 13 SP - 3503 EP - 3508 UR - https://doi.org/10.3892/etm.2017.4389 ER - TY - JOUR LB - 31. AU - Korpi-Steiner, NL AU - Williamson, EE AU - Karon, BS TI - Comparison of three whole blood creatinine methods for estimation of glomerular filtration rate before radiographic contrast administration J2 - Am J Clin Pathol PY - 2009 VL - 132 SP - 920 EP - 926 UR - https://doi.org/10.1309/AJCPTE5FEY0VCGOZ ER - TY - BOOK LB - 32. AU - Krige, T TI - Screening for Chronic Kidney Disease (CKD) in a High Risk Population Using a Point of Care Instrument for Creatinine Measurement: a Community Based Study (The Bellville South Africa Study CY - Stellenbosch PB - Stellenbosch University PY - 2017 ER - TY - JOUR LB - 33. AU - Nichols, JH AU - Bartholomew, C AU - Bonzagi, A AU - Garb, JL AU - Jin, L TI - Evaluation of the IRMA TRUpoint and i-STAT creatinine assays J2 - Clin Chim Acta PY - 2007 VL - 377 SP - 201 EP - 205 UR - https://doi.org/10.1016/j.cca.2006.09.024 ER - TY - JOUR LB - 34. AU - Obrador, G AU - Olvera, N AU - De La Pe, DO AU - Gutieez, V AU - Villa, A TI - Validation of serum creatinine (SCR) measurement with the point-of-care testing (POCT) device i-STAT in a Mexican government sponsored-chronic kidney disease (CKD) screening program J2 - Nephrol Dial Transplant PY - 2012 VL - 27 SP - ii100 ER - TY - JOUR LB - 35. AU - Shephard, M AU - Corso, O AU - Mathew, T TI - Creatinine can be measured at the point-of-care J2 - Nephrology PY - 2008 VL - 13 SP - A101 EP - A10A ER - TY - JOUR LB - 36. AU - Shephard, M AU - Peake, M AU - Corso, O AU - Shephard, A AU - Mazzachi, B AU - Spaeth, B TI - Assessment of the Nova StatSensor whole blood point-of-care creatinine analyzer for the measurement of kidney function in screening for chronic kidney disease J2 - Clin Chem Lab Med PY - 2010 VL - 48 SP - 1113 EP - 1119 UR - https://doi.org/10.1515/CCLM.2010.238 ER - TY - JOUR LB - 37. AU - Snaith, B AU - Harris, MA AU - Shinkins, B AU - Jordaan, M AU - Messenger, M AU - Lewington, A TI - Point-of-care creatinine testing for kidney function measurement prior to contrast-enhanced diagnostic imaging: evaluation of the performance of three systems for clinical utility J2 - Clin Chem Lab Med PY - 2018 VL - 56 SP - 1269 EP - 1276 UR - https://doi.org/10.1515/cclm-2018-0128 ER - TY - JOUR LB - 38. AU - Snaith, B AU - Harris, MA AU - Shinkins, B AU - Messenger, M AU - Lewington, A AU - Jordaan, M AU - Spencer, N TI - Point of care creatinine testing in diagnostic imaging: a feasibility study within the outpatient computed tomography setting J2 - Eur J Radiol PY - 2019 VL - 112 SP - 82 EP - 87 UR - https://doi.org/10.1016/j.ejrad.2019.01.007 ER - TY - JOUR LB - 39. AU - Griffin, BR AU - Butler-Dawson, J AU - Dally, M AU - Krisher, L AU - Cruz, A AU - Weitzenkamp, D TI - Unadjusted point of care creatinine results overestimate acute kidney injury incidence during field testing in Guatemala J2 - PLOS ONE PY - 2018 VL - 13 SP - e0204614 UR - https://doi.org/10.1371/journal.pone.0204614 ER - TY - GEN LB - 40. AU - Hamza, M TI - Evaluation of the StatSensor Whole Blood Creatinine Monitoring System for Screening Patients in the Radiology Department ER - TY - JOUR LB - 41. AU - Haneder, S AU - Gutfleisch, A AU - Meier, C AU - Brade, J AU - Hannak, D AU - Schoenberg, SO TI - Evaluation of a handheld creatinine measurement device for real-time determination of serum creatinine in radiology departments J2 - World J Radiol PY - 2012 VL - 4 SP - 328 EP - 334 UR - https://doi.org/10.4329/wjr.v4.i7.328 ER - TY - JOUR LB - 42. AU - Kosack, CS AU - de Kieviet, W AU - Bayrak, K AU - Milovic, A AU - Page, AL TI - Evaluation of the Nova StatSensor®Xpress™ Creatinine point-of-care handheld analyzer J2 - PLOS ONE PY - 2015 VL - 10 SP - e0122433 UR - https://doi.org/10.1371/journal.pone.0122433 ER - TY - CONF LB - 43. AU - McGough, L AU - Malic, A AU - Beukinga, I AU - Blairon, L TI - Management of the Prevention of Kidney Injury in Patients at Risk of Renal Failure by StatSensor Blood Creatinine Monitoring System: Evaluation of Method T2 - Proceedings of the American Association for Clinical Chemistry CPOCT Conference DA - 26–29 September 2018 CY - Washington, DC, USA ER - TY - JOUR LB - 44. AU - Minnings, K AU - Kerns, E AU - Fiore, M AU - Fiore, M AU - Parekh, RS AU - DuBois, J TI - Chronic kidney disease prevalence in Rivas, Nicaragua: use of a field device for creatinine measurement J2 - Clin Biochem PY - 2015 VL - 48 SP - 456 EP - 458 UR - https://doi.org/10.1016/j.clinbiochem.2015.01.005 ER - TY - JOUR LB - 45. AU - Rensburg, M AU - Hudson, C AU - Erasmus, R TI - Evaluation and performance of the nova StatSensor creatinine point-of-care monitoring system J2 - Clin Chem Lab Med PY - 2014 VL - 1 SP - S1525 ER - TY - JOUR LB - 46. AU - Aumatell, A AU - Sharpe, D AU - Reed, W TI - Validation of the StatSensor creatinine meter for testing blood before contrast computed tomography studies J2 - Point Care PY - 2010 VL - 9 SP - 25 EP - 31 UR - https://doi.org/10.1097/POC.0b013e3181d2d8a5 ER - TY - JOUR LB - 47. AU - Bahar, B AU - DeChristopher, PJ AU - Holmes, EW AU - Kahn, SE TI - Investigation of falsely decreased creatinine results observed from the Abbott I-STAT point-of-care device in use for testing specimens from ambulatory oncology patients J2 - Point Care PY - 2016 VL - 15 SP - 72 EP - 77 UR - https://doi.org/10.1097/POC.0000000000000093 ER - TY - JOUR LB - 48. AU - Baier, KA AU - Markham, LE AU - Flaigle, SP AU - Nelson, PW AU - Shield, CF AU - Muruve, NA TI - Point-of-care testing in an organ procurement organization donor management setting J2 - Clin Transplant PY - 2003 VL - 17 IS - Suppl. 9 SP - 48 EP - 51 UR - https://doi.org/10.1034/j.1399-0012.17.s9.9.x ER - TY - JOUR LB - 49. AU - Bender, LM AU - Gearhart, M AU - Faso, A AU - Hammett-Stabler, C TI - Comparison of whole blood creatinine measurement to serum creatinine measurements in renal dose calculations J2 - Clin Chem PY - 2012 VL - 58 SP - A165 EP - A1A6 ER - TY - JOUR LB - 50. AU - Betman, SA AU - Hod, EA AU - Kratz, A TI - Hydroxyurea interference in point-of-care creatinine and glucose measurements J2 - Am J Clin Pathol PY - 2015 VL - 1 SP - A030 UR - https://doi.org/10.1093/ajcp/143.suppl1.031 ER - TY - GEN LB - 51. AU - Bobilewicz, D TI - Comparison of Creatinine Concentration in Serum, Plasma and Whole Blood on Different Routinely Used Analysers PY - 2008 ER - TY - JOUR LB - 52. AU - Cao, J AU - Edwards, R AU - Chairez, J AU - Devaraj, S TI - Validation of capillary blood analysis and capillary testing mode on the epoc point of care system J2 - Pract Lab Med PY - 2017 VL - 9 SP - 24 EP - 27 UR - https://doi.org/10.1016/j.plabm.2017.07.003 ER - TY - JOUR LB - 53. AU - Cory, R AU - Clark, K AU - Snowball, O AU - Bramham, K TI - Evaluation of the StatSensor Xpress for the point of care determination of capillary creatinine concentration in a pregnant population J2 - Pregnancy Hypertens PY - 2018 VL - 13 SP - S138 UR - https://doi.org/10.1016/j.preghy.2018.08.410 ER - TY - JOUR LB - 54. AU - Dimeski, G AU - Tilley, V AU - Jones, BW AU - Brown, NN TI - Which point-of-care creatinine analyser for radiology: direct comparison of the i-Stat and StatStrip creatinine methods with different sample types J2 - Ann Clin Biochem PY - 2013 VL - 50 SP - 47 EP - 52 UR - https://doi.org/10.1258/acb.2012.012081 ER - TY - JOUR LB - 55. AU - Dohnal, L AU - Kloudova, M AU - Cechak, P TI - Comparison of Some Characteristics in Results of Four Analytical Systems for 12 Basic Biochemical Analytes J2 - Klini Biochemi Metabol PY - 2008 VL - 16 SP - 33 EP - 39 ER - TY - JOUR LB - 56. AU - Gault, MH AU - Seymour, ME AU - Howell, WE TI - Evaluation of i-STAT creatinine assay J2 - Nephron PY - 2001 VL - 88 SP - 178 EP - 182 UR - https://doi.org/10.1159/000045982 ER - TY - JOUR LB - 57. AU - Georgievskaya, ZA AU - Creger, RA AU - Schmotzer, CL TI - Under-estimation of plasma creatinine using iSTAT point-of-care analyzer: impact on carboplatin dosing in an academic cancer center J2 - Clin Chem PY - 2011 VL - 1 SP - A135 ER - TY - GEN LB - 58. AU - Janetto, P AU - Shi, RZ AU - Scheider, C AU - Breitenfeld, D TI - Comparison of Whole Blood Versus Plasma Creatinine Measurements on the ABL800 FLEX and Olympus AU5431 Analyzer (Modified Jaffe Method) PY - 2006 ER - TY - JOUR LB - 59. AU - Lee-Lewandrowski, E AU - Chang, C AU - Gregory, K AU - Lewandrowski, K TI - Evaluation of rapid point-of-care creatinine testing in the radiology service of a large academic medical center: impact on clinical operations and patient disposition J2 - Clin Chim Acta PY - 2012 VL - 413 SP - 88 EP - 92 UR - https://doi.org/10.1016/j.cca.2011.05.006 ER - TY - BOOK LB - 60. AU - Lehtonen, A TI - Sodium, Potassium and Creatinine Result Level Comparison Between Point-of-Care Analyser and Core Laboratory Automatic Analyser CY - Tampere PB - Tampere University of Applied Sciences PY - 2013 ER - TY - JOUR LB - 61. AU - Mahlow, J AU - Reineks, E TI - Accuracy of i-STAT point-of-care creatinine measurements in outpatient chemotherapy patients: a direct comparison to laboratory based methods J2 - Clin Chem PY - 2016 VL - 62 IS - Suppl. 1 SP - S225 ER - TY - JOUR LB - 62. AU - Morita, S AU - Suzuki, K AU - Masukawa, A AU - Ueno, E TI - Assessing renal function with a rapid, handy, point-of-care whole blood creatinine meter before using contrast materials J2 - Jpn J Radiol PY - 2011 VL - 29 SP - 187 EP - 193 UR - https://doi.org/10.1007/s11604-010-0536-8 ER - TY - JOUR LB - 63. AU - Murata, K AU - Glaser, L AU - Nardiello, M AU - Ramanathan, LV AU - Carlow, DC TI - Data from the analytical performance of the Abaxis Piccolo Xpress point of care analyzer in whole blood, serum, and plasma J2 - Data Brief PY - 2018 VL - 16 SP - 81 EP - 89 UR - https://doi.org/10.1016/j.dib.2017.11.006 ER - TY - JOUR LB - 64. AU - Naugler, C AU - Redman, L AU - Sadzradeh, H TI - Comparison of estimated glomerular filtration rates using creatinine values generated by iSTAT and Cobas 6000 J2 - Clin Chim Acta PY - 2014 VL - 429 SP - 79 EP - 80 UR - https://doi.org/10.1016/j.cca.2013.11.033 ER - TY - JOUR LB - 65. AU - Park, H AU - Ko, DH AU - Kim, JQ AU - Song, SH TI - Performance evaluation of the Piccolo Xpress point-of-care chemistry analyzer J2 - Korean J Lab Med PY - 2009 VL - 29 SP - 430 EP - 438 UR - https://doi.org/10.3343/kjlm.2009.29.5.430 ER - TY - JOUR LB - 66. AU - Schnabl, KL AU - Tarek, M AU - Cursio, C AU - Yip, PM TI - Evaluation of the Piccolo Xpress chemistry analyzer for point of care testing of plasma liver function markers, electrolytes and metabolites J2 - Clin Biochem PY - 2008 VL - 41 SP - 1284 EP - 1285 UR - https://doi.org/10.1016/j.clinbiochem.2008.08.058 ER - TY - JOUR LB - 67. AU - Schnabl, KL AU - Bagherpoor, S AU - Diker, P AU - Cursio, C AU - Dubois, J AU - Yip, PM TI - Evaluation of the analytical performance of the Nova StatSensor creatinine meter and reagent strip technology for whole blood testing J2 - Clin Biochem PY - 2010 VL - 43 SP - 1026 EP - 1029 UR - https://doi.org/10.1016/j.clinbiochem.2010.04.055 ER - TY - JOUR LB - 68. AU - Skurup, A AU - Kristensen, T AU - Wennecke, G AU - National Kidney Disease Education Program Laboratory Working Group TI - New creatinine sensor for point-of-care testing of creatinine meets the National Kidney Disease Education Program guidelines J2 - Clin Chem Lab Med PY - 2008 VL - 46 SP - 3 EP - 8 UR - https://doi.org/10.1515/CCLM.2008.004 ER - TY - JOUR LB - 69. AU - Srihong, C AU - Pangsapa, K AU - Chuaboonmee, K AU - Kotipan, Y AU - Charuruks, N TI - Evaluation of the analytical performance of the nova StatSensor creatinine meter for blood testing J2 - J Med Assoc Thai PY - 2012 VL - 95 SP - 1225 EP - 1231 ER - TY - JOUR LB - 70. AU - Stojkovic, V AU - Delanaye, P AU - Schleck, M AU - Le Goff, C AU - Cavalier, E TI - Estimated glomerular filtration rate (GFR) using a point of care (POC) measure of creatinine in patients with iohexol determinate GFR J2 - Clin Chem Lab Med PY - 2017 VL - 55 IS - Suppl. 1 SP - S149 ER - TY - JOUR LB - 71. AU - Straseski, J AU - Phelan, L AU - Clarke, W TI - Creatinine levels in patients with renal disease: discordance between POC meter and automated enzymatic methods J2 - Clin Chem PY - 2009 VL - 55 SP - A102 EP - A10A ER - TY - JOUR LB - 72. AU - Straseski, JA AU - Clarke, W AU - Molinaro, R TI - Investigating possible causes of discrepant creatinine results: discordance in patients with renal insufficiency J2 - Am J Clin Pathol PY - 2010 VL - 134 SP - 507 ER - TY - JOUR LB - 73. AU - Straseski, JA AU - Lyon, ME AU - Clarke, W AU - Dubois, JA AU - Phelan, LA AU - Lyon, AW TI - Investigating interferences of a whole-blood point-of-care creatinine analyzer: comparison to plasma enzymatic and definitive creatinine methods in an acute-care setting J2 - Clin Chem PY - 2011 VL - 57 SP - 1566 EP - 1573 UR - https://doi.org/10.1373/clinchem.2011.165480 ER - TY - JOUR LB - 74. AU - Treves, C AU - Boehre, JL TI - Controlled trial between measurement of glomerular filtration rate on venous blood (automated laboratory) and capillary blood (bedside system) J2 - Clin Chem Lab Med PY - 2011 VL - 1 SP - S690 ER - TY - JOUR LB - 75. AU - Too, CW AU - Ng, WY AU - Tan, CC AU - Mahmood, MI AU - Tay, KH TI - Screening for impaired renal function in outpatients before iodinated contrast injection: comparing the Choyke questionnaire with a rapid point-of-care-test J2 - Eur J Radiol PY - 2015 VL - 84 SP - 1227 EP - 1231 UR - https://doi.org/10.1016/j.ejrad.2015.04.001 ER - TY - JOUR LB - 76. AU - van Lint, CL AU - van der Boog, PJ AU - Romijn, FP AU - Schenk, PW AU - van Dijk, S AU - Rovekamp, TJ TI - Application of a point of care creatinine device for trend monitoring in kidney transplant patients: fit for purpose? J2 - Clini Chem Lab Med PY - 2015 VL - 53 SP - 1547 EP - 1556 UR - https://doi.org/10.1515/cclm-2014-0932 ER - TY - JOUR LB - 77. AU - Ledermann, HP AU - Mengiardi, B AU - Schmid, A AU - Froehlich, JM TI - Screening for renal insufficiency following ESUR (European Society of Urogenital Radiology) guidelines with on-site creatinine measurements in an outpatient setting J2 - Eur Radiol PY - 2010 VL - 20 SP - 1926 EP - 1933 UR - https://doi.org/10.1007/s00330-010-1754-2 ER - TY - JOUR LB - 78. AU - Snaith, B AU - Harris, MA AU - Clarke, R TI - Screening prior to gadolinium based contrast agent administration: a UK survey of guideline implementation and adherence J2 - Radiography PY - 2016 VL - 22 SP - S24 EP - S27 UR - https://doi.org/10.1016/j.radi.2016.07.006 ER - TY - JOUR LB - 79. AU - Stahr, K AU - Lindell, E AU - Ahnlide, J AU - Law, I TI - The impact of Nova StatSensor creatinine point-of-care monitoring system on the number of i.v. contrast-enhanced CT scanning procedures performed in a clinical PET/CT unit J2 - Eur J Nucl Med Mol Imag PY - 2010 VL - 2 SP - S496 EP - S4S7 ER - TY - JOUR LB - 80. AU - Murata, K AU - Glaser, L AU - Nardiello, M AU - Richardson, S AU - Ramanathan, LV AU - Carlow, DC TI - Analytical performance of the Abaxis Piccolo Xpress®point of care analyzer in whole blood, serum, and plasma J2 - Clin Biochem PY - 2015 VL - 48 SP - 1344 EP - 1346 UR - https://doi.org/10.1016/j.clinbiochem.2015.08.002 ER - TY - JOUR LB - 81. AU - Newhouse, JH AU - Kho, D AU - Rao, QA AU - Starren, J TI - Frequency of serum creatinine changes in the absence of iodinated contrast material: implications for studies of contrast nephrotoxicity J2 - AJR Am J Roentgenol PY - 2008 VL - 191 SP - 376 EP - 382 UR - https://doi.org/10.2214/AJR.07.3280 ER - TY - JOUR LB - 82. AU - Bruce, RJ AU - Djamali, A AU - Shinki, K AU - Michel, SJ AU - Fine, JP AU - Pozniak, MA TI - Background fluctuation of kidney function versus contrast-induced nephrotoxicity J2 - AJR Am J Roentgenol PY - 2009 VL - 192 SP - 711 EP - 718 UR - https://doi.org/10.2214/AJR.08.1413 ER - TY - JOUR LB - 83. AU - Azzouz, M AU - Rømsing, J AU - Thomsen, HS TI - Fluctuations in eGFR in relation to unenhanced and enhanced MRI and CT outpatients J2 - Eur J Radiol PY - 2014 VL - 83 SP - 886 EP - 892 UR - https://doi.org/10.1016/j.ejrad.2014.02.014 ER - TY - JOUR LB - 84. AU - Cheungpasitporn, W AU - Thongprayoon, C AU - Mao, MA AU - Mao, SA AU - D’Costa, MR AU - Kittanamongkolchai, W AU - Kashani, KB TI - Contrast-induced acute kidney injury in kidney transplant recipients: a systematic review and meta-analysis J2 - World J Transplant PY - 2017 VL - 7 SP - 81 EP - 87 UR - https://doi.org/10.5500/wjt.v7.i1.81 ER - TY - JOUR LB - 85. AU - Ehrmann, S AU - Quartin, A AU - Hobbs, BP AU - Robert-Edan, V AU - Cely, C AU - Bell, C TI - Contrast-associated acute kidney injury in the critically ill: systematic review and Bayesian meta-analysis J2 - Intensive Care Med PY - 2017 VL - 43 SP - 785 EP - 794 UR - https://doi.org/10.1007/s00134-017-4700-9 ER - TY - JOUR LB - 86. AU - Aycock, RD AU - Westafer, LM AU - Boxen, JL AU - Majlesi, N AU - Schoenfeld, EM AU - Bannuru, RR TI - Acute kidney injury after computed tomography: a meta-analysis J2 - Ann Emerg Med PY - 2018 VL - 71 SP - 44 EP - 53 UR - https://doi.org/10.1016/j.annemergmed.2017.06.041 ER - TY - JOUR LB - 87. AU - Kooiman, J AU - Pasha, SM AU - Zondag, W AU - Sijpkens, YW AU - van der Molen, AJ AU - Huisman, MV AU - Dekkers, OM TI - Meta-analysis: serum creatinine changes following contrast enhanced CT imaging J2 - Eur J Radiol PY - 2012 VL - 81 SP - 2554 EP - 2561 UR - https://doi.org/10.1016/j.ejrad.2011.11.020 ER - TY - JOUR LB - 88. AU - Moos, SI AU - van Vemde, DN AU - Stoker, J AU - Bipat, S TI - Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis J2 - Eur J Radiol PY - 2013 VL - 82 SP - e387 EP - e399 UR - https://doi.org/10.1016/j.ejrad.2013.04.029 ER - TY - JOUR LB - 89. AU - McDonald, RJ AU - McDonald, JS AU - Carter, RE AU - Hartman, RP AU - Katzberg, RW AU - Kallmes, DF AU - Williamson, EE TI - Intravenous contrast material exposure is not an independent risk factor for dialysis or mortality J2 - Radiology PY - 2014 VL - 273 SP - 714 EP - 725 UR - https://doi.org/10.1148/radiol.14132418 ER - TY - JOUR LB - 90. AU - Davenport, MS AU - Khalatbari, S AU - Dillman, JR AU - Cohan, RH AU - Caoili, EM AU - Ellis, JH TI - Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material J2 - Radiology PY - 2013 VL - 267 SP - 94 EP - 105 UR - https://doi.org/10.1148/radiol.12121394 ER - TY - JOUR LB - 91. AU - Davenport, MS AU - Khalatbari, S AU - Cohan, RH AU - Dillman, JR AU - Myles, JD AU - Ellis, JH TI - Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material: risk stratification by using estimated glomerular filtration rate J2 - Radiology PY - 2013 VL - 268 SP - 719 EP - 728 UR - https://doi.org/10.1148/radiol.13122276 ER - TY - JOUR LB - 92. AU - McDonald, JS AU - McDonald, RJ AU - Carter, RE AU - Katzberg, RW AU - Kallmes, DF AU - Williamson, EE TI - Risk of intravenous contrast material-mediated acute kidney injury: a propensity score-matched study stratified by baseline-estimated glomerular filtration rate J2 - Radiology PY - 2014 VL - 271 SP - 65 EP - 73 UR - https://doi.org/10.1148/radiol.13130775 ER - TY - JOUR LB - 93. AU - Rubin, DB TI - Estimating causal effects from large data sets using propensity scores J2 - Ann Intern Med PY - 1997 VL - 127 SP - 757 EP - 763 UR - https://doi.org/10.7326/0003-4819-127-8_Part_2-199710151-00064 ER - TY - JOUR LB - 94. AU - Rosenbaum, P AU - Rubin, D TI - Constructing a control group using multivariate matched sampling methods that incorporate the propensity score J2 - Am Stat PY - 1985 VL - 39 SP - 33 EP - 38 UR - https://doi.org/10.1080/00031305.1985.10479383 ER - TY - JOUR LB - 95. AU - Walsh, M AU - Srinathan, SK AU - McAuley, DF AU - Mrkobrada, M AU - Levine, O AU - Ribic, C TI - The statistical significance of randomized controlled trial results is frequently fragile: a case for a Fragility Index J2 - J Clin Epidemiol PY - 2014 VL - 67 SP - 622 EP - 628 UR - https://doi.org/10.1016/j.jclinepi.2013.10.019 ER - TY - JOUR LB - 96. AU - Dekkers, IA AU - van der Molen, AJ TI - Propensity score matching as a substitute for randomized controlled trials on acute kidney injury after contrast media administration: a systematic review J2 - AJR Am J Roentgenol PY - 2018 VL - 211 SP - 822 EP - 826 UR - https://doi.org/10.2214/AJR.17.19499 ER - TY - JOUR LB - 97. AU - Hinson, JS AU - Ehmann, MR AU - Fine, DM AU - Fishman, EK AU - Toerper, MF AU - Rothman, RE AU - Klein, EY TI - Risk of acute kidney injury after intravenous contrast media administration J2 - Ann Emerg Med PY - 2017 VL - 69 SP - 577 EP - 586 UR - https://doi.org/10.1016/j.annemergmed.2016.11.021 ER - TY - JOUR LB - 98. AU - McDonald, JS AU - McDonald, RJ AU - Williamson, EE AU - Kallmes, DF TI - Is intravenous administration of iodixanol associated with increased risk of acute kidney injury, dialysis, or mortality? A propensity score-adjusted study J2 - Radiology PY - 2017 VL - 285 SP - 414 EP - 424 UR - https://doi.org/10.1148/radiol.2017161573 ER - TY - BOOK LB - 99. AU - Higgins, J AU - Green, S TI - Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011 PB - The Cochrane Collaboration PY - 2011 UR - www.handbook.cochrane.org Y2 - 21 May 2019 ER - TY - JOUR LB - 100. AU - Hiremath, S AU - Akbari, A AU - Shabana, W AU - Fergusson, DA AU - Knoll, GA TI - Prevention of contrast-induced acute kidney injury: is simple oral hydration similar to intravenous? A systematic review of the evidence J2 - PLOS ONE PY - 2013 VL - 8 SP - e60009 UR - https://doi.org/10.1371/journal.pone.0060009 ER - TY - JOUR LB - 101. AU - Agarwal, SK AU - Mohareb, S AU - Patel, A AU - Yacoub, R AU - DiNicolantonio, JJ AU - Konstantinidis, I TI - Systematic oral hydration with water is similar to parenteral hydration for prevention of contrast-induced nephropathy: an updated meta-analysis of randomised clinical data J2 - Open Heart PY - 2015 VL - 2 SP - e000317 UR - https://doi.org/10.1136/openhrt-2015-000317 ER - TY - JOUR LB - 102. AU - Ahmed, K AU - McVeigh, T AU - Cerneviciute, R AU - Mohamed, S AU - Tubassam, M AU - Karim, M AU - Walsh, S TI - Effectiveness of contrast-associated acute kidney injury prevention methods; a systematic review and network meta-analysis J2 - BMC Nephrol PY - 2018 VL - 19 SP - 323 UR - https://doi.org/10.1186/s12882-018-1113-0 ER - TY - JOUR LB - 103. AU - Dussol, B AU - Morange, S AU - Loundoun, A AU - Auquier, P AU - Berland, Y TI - A randomized trial of saline hydration to prevent contrast nephropathy in chronic renal failure patients J2 - Nephrol Dial Transplant PY - 2006 VL - 21 SP - 2120 EP - 2126 UR - https://doi.org/10.1093/ndt/gfl133 ER - TY - JOUR LB - 104. AU - Nijssen, EC AU - Rennenberg, RJ AU - Nelemans, PJ AU - Essers, BA AU - Janssen, MM AU - Vermeeren, MA TI - Prophylactic hydration to protect renal function from intravascular iodinated contrast material in patients at high risk of contrast-induced nephropathy (AMACING): a prospective, randomised, phase 3, controlled, open-label, non-inferiority trial J2 - Lancet PY - 2017 VL - 389 SP - 1312 EP - 1322 UR - https://doi.org/10.1016/S0140-6736(17)30057-0 ER - TY - JOUR LB - 105. AU - Nijssen, EC AU - Nelemans, PJ AU - Rennenberg, RJ AU - van Ommen, V AU - Wildberger, JE TI - Prophylactic intravenous hydration to protect renal function from intravascular iodinated contrast material (AMACING): long-term results of a prospective, randomised, controlled trial J2 - EClinicalMedicine PY - 2018 VL - 4–5 SP - 109 EP - 116 UR - https://doi.org/10.1016/j.eclinm.2018.10.007 ER - TY - JOUR LB - 106. AU - Nijssen, EC AU - Nelemans, PJ AU - Rennenberg, RJ AU - van Ommen, V AU - Wildberger, JE TI - Evaluation of safety guidelines on the use of iodinated contrast material: conundrum continued J2 - Invest Radiol PY - 2018 VL - 53 SP - 616 EP - 622 UR - https://doi.org/10.1097/RLI.0000000000000479 ER - TY - ELEC LB - 107. AU - The Renal Association, British Cardiovascular Intervention Society and the Royal College of Radiologists TI - Prevention of Contrast Induced Acute Kidney Injury (CI-AKI) in Adult Patients PY - 2013 UR - www.rcr.ac.uk/publications.aspx?PageID=310%26PublicationID=391 M1 - 31 January 2019 ER - TY - GEN LB - 108. AU - National Institute for Health and Care Excellence (NICE) TI - Acute Kidney Injury: Prevention, Detection and Management of Acute Kidney Injury up to the Point of Renal Replacement Therapy. Clinical Guidelines, CG169 CY - London PB - NICE PY - 2013 UR - https://guidance.nice.org.uk/cg169 Y2 - 31 January 2019 ER - TY - GEN LB - 109. AU - Royal College of Radiologists TI - Standards for Intravascular Contrast Administration to Adult Patients ET - 3rd CY - London PB - Royal College of Radiologists PY - 2015 ER - TY - JOUR LB - 110. AU - National Clinical Guideline Centre TI - Acute kidney injury: prevention, detection and management up to the point of renal replacement therapy J2 - Royal Coll Physicians PY - 2013 VL - 8 SP - 8 ER - TY - GEN LB - 111. AU - Department of Health and Social Care TI - National Schedule of Reference Costs 2015–2016 CY - London PB - Department of Health and Social Care PY - 2016 UR - www.gov.uk/government/publications/nhs-reference-costs-2015-to-2016 Y2 - 15 April 2019 ER - TY - JOUR LB - 112. AU - Nowacek, A AU - McClintock, D TI - Point-of-care creatinine/estimated glomerular filtration rate testing within the radiology department of an academic medical center improves workflow and reduces costs J2 - Am J Clin Pathol PY - 2015 VL - 1 SP - A044 UR - https://doi.org/10.1093/ajcp/143.suppl1.045 ER - TY - BOOK LB - 113. AU - Chalkidou, A AU - Erskine, J TI - RX205 Point-of-care Creatinine Tests CY - London PB - KiTEC – King’s Technology Evaluation Centre PY - 2019 ER - TY - JOUR LB - 114. AU - Moos, SI AU - Stoker, J AU - Nagan, G AU - de Weijert, RS AU - van Vemde, DN AU - Bipat, S TI - Prediction of presence of kidney disease in a general patient population undergoing intravenous iodinated contrast enhanced computed tomography J2 - Eur Radiol PY - 2014 VL - 24 SP - 1266 EP - 1275 UR - https://doi.org/10.1007/s00330-014-3149-2 ER - TY - JOUR LB - 115. AU - Park, S AU - Kim, MH AU - Kang, E AU - Park, S AU - Jo, HA AU - Lee, H TI - Contrast-induced nephropathy after computed tomography in stable CKD patients with proper prophylaxis: 8-year experience of outpatient prophylaxis program J2 - Medicine PY - 2016 VL - 95 SP - e3560 UR - https://doi.org/10.1097/MD.0000000000003560 ER - TY - JOUR LB - 116. AU - Schreuder, SM AU - Stoker, J AU - Bipat, S TI - Prediction of presence of kidney disease in patients undergoing intravenous iodinated contrast enhanced computed tomography: a validation study J2 - Eur Radiol PY - 2017 VL - 27 SP - 1613 EP - 1621 UR - https://doi.org/10.1007/s00330-016-4478-0 ER - TY - JOUR LB - 117. AU - Kim, SM AU - Cha, RH AU - Lee, JP AU - Kim, DK AU - Oh, KH AU - Joo, KW TI - Incidence and outcomes of contrast-induced nephropathy after computed tomography in patients with CKD: a quality improvement report J2 - Am J Kidney Dis PY - 2010 VL - 55 SP - 1018 EP - 1025 UR - https://doi.org/10.1053/j.ajkd.2009.10.057 ER - TY - GEN LB - 118. AU - Office for National Statistics TI - National Life Tables: England CY - Newport PB - Office for National Statistics PY - 2018 UR - www.ons.gov.uk/peoplepopulationandcommunity/birthsdeathsandmarriages/lifeexpectancies/datasets/nationallifetablesenglandreferencetables Y2 - 7 February 2020 ER - TY - JOUR LB - 119. AU - Ara, R AU - Brazier, JE TI - Populating an economic model with health state utility values: moving toward better practice J2 - Value Health PY - 2010 VL - 13 SP - 509 EP - 518 UR - https://doi.org/10.1111/j.1524-4733.2010.00700.x ER - TY - JOUR LB - 120. AU - Wyld, M AU - Morton, RL AU - Hayen, A AU - Howard, K AU - Webster, AC TI - A systematic review and meta-analysis of utility-based quality of life in chronic kidney disease treatments J2 - PLOS Med PY - 2012 VL - 9 SP - e1001307 UR - https://doi.org/10.1371/journal.pmed.1001307 ER - TY - JOUR LB - 121. AU - Hall, PS AU - Mitchell, ED AU - Smith, AF AU - Cairns, DA AU - Messenger, M AU - Hutchinson, M TI - The future for diagnostic tests of acute kidney injury in critical care: evidence synthesis, care pathway analysis and research prioritisation J2 - Health Technol Assess PY - 2018 VL - 22 IS - 32 UR - https://doi.org/10.3310/hta22320 ER - TY - JOUR LB - 122. AU - Dolan, P TI - Modeling valuations for EuroQol health states J2 - Med Care PY - 1997 VL - 35 SP - 1095 EP - 1108 UR - https://doi.org/10.1097/00005650-199711000-00002 ER - TY - BOOK LB - 123. AU - Curtis, LA AU - Burns, A TI - Unit Costs of Health and Social Care 2017 CY - Canterbury PB - Personal Social Services Research Unit, University of Kent PY - 2017 ER - TY - GEN LB - 124. AU - Department of Health and Social Care TI - National Schedule of Reference Costs – Year 2017–18 – NHS Trust and NHS Foundation Trusts CY - London PB - Department of Health and Social Care PY - 2018 UR - https://improvement.nhs.uk/resources/reference-costs/ Y2 - 15 April 2019 ER - TY - JOUR LB - 125. AU - Duffy, S AU - de Kock, S AU - Misso, K AU - Noake, C AU - Ross, J AU - Stirk, L TI - Supplementary searches of PubMed to improve currency of MEDLINE and MEDLINE In-Process searches via Ovid J2 - J Med Libr Assoc PY - 2016 VL - 104 SP - 309 EP - 312 UR - https://doi.org/10.3163/1536-5050.104.4.011 ER - TY - JOUR LB - 126. AU - Adams, DA AU - Buus-Frank, M TI - Point-of-care technology: the i-STAT system for bedside blood analysis J2 - J Pediatr Nurs PY - 1995 VL - 10 SP - 194 EP - 198 UR - https://doi.org/10.1016/S0882-5963(05)80084-3 ER - TY - GEN LB - 127. AU - Canadian Agency for Drugs and Technologies in Health TI - Point of Care Testing for Human Chorionic Gonadotropin, Creatinine, and Blood Urea Nitrogen: Cost-effectiveness CY - Ottawa, ON PB - Canadian Agency for Drugs and Technologies in Health PY - 2013 UR - https://www.crd.york.ac.uk/CRDWeb/ShowRecord.asp?ID=32014000136 Y2 - 21 May 2019 ER - TY - GEN LB - 128. AU - Canadian Agency for Drugs and Technologies in Health (CADTH) TI - CADTH Database Search Filters CY - Ottawa, ON PB - Canadian Agency for Drugs and Technologies in Health PY - 2016 UR - www.cadth.ca/resources/finding-evidence/strings-attached-cadths-database-search-filters Y2 - 13 January 2019 ER - TY - JOUR LB - 129. AU - Chicaíza-Becerra, LA AU - García-Molina, M AU - Gamboa, Ó TI - Cost-effectiveness of iso- versus low-osmolality contrast media in outpatients with high risk of contrast medium-induced nephropathy J2 - Biomedica PY - 2012 VL - 32 SP - 182 EP - 188 UR - https://doi.org/10.1590/S0120-41572012000300005 ER - TY - JOUR LB - 130. AU - Iannazzo, S AU - Vandekerckhove, S AU - De Francesco, M AU - Nayak, A AU - Ronco, C AU - Morana, G AU - Valentino, M TI - Economic evaluation of intravenous iodinated contrast media in Italy J2 - Int J Technol Assess Health Care PY - 2014 VL - 30 SP - 69 EP - 77 UR - https://doi.org/10.1017/S0266462313000706 ER - TY - JOUR LB - 131. AU - De Smedt, DM AU - Elseviers, MM AU - Lins, RL AU - Annemans, L TI - Economic evaluation of different treatment modalities in acute kidney injury J2 - Nephrol Dial Transplant PY - 2012 VL - 27 SP - 4095 EP - 4101 UR - https://doi.org/10.1093/ndt/gfs410 ER - TY - JOUR LB - 132. AU - Ethgen, O AU - Schneider, AG AU - Bagshaw, SM AU - Bellomo, R AU - Kellum, JA TI - Economics of dialysis dependence following renal replacement therapy for critically ill acute kidney injury patients J2 - Nephrol Dial Transplant PY - 2015 VL - 30 SP - 54 EP - 61 UR - https://doi.org/10.1093/ndt/gfu314 ER - TY - JOUR LB - 133. AU - Kerr, M AU - Bedford, M AU - Matthews, B AU - O’Donoghue, D TI - The economic impact of acute kidney injury in England J2 - Nephrol Dial Transplant PY - 2014 VL - 29 SP - 1362 EP - 1368 UR - https://doi.org/10.1093/ndt/gfu016 ER - TY - JOUR LB - 134. AU - Petrovic, S AU - Bogavac-Stanojevic, N AU - Lakic, D AU - Peco-Antic, A AU - Vulicevic, I TI - Cost-effectiveness analysis of acute kidney injury biomarkers in pediatric cardiac surgery J2 - Biochemia Medica PY - 2015 VL - 25 SP - 262 EP - 271 UR - https://doi.org/10.11613/BM.2015.027 ER - TY - JOUR LB - 135. AU - James, MT AU - Ghali, WA AU - Knudtson, ML AU - Ravani, P AU - Tonelli, M AU - Faris, P TI - Associations between acute kidney injury and cardiovascular and renal outcomes after coronary angiography J2 - Circulation PY - 2011 VL - 123 SP - 409 EP - 416 UR - https://doi.org/10.1161/CIRCULATIONAHA.110.970160 ER - TY - JOUR LB - 136. AU - Mueller, C AU - Buerkle, G AU - Buettner, HJ AU - Petersen, J AU - Perruchoud, AP AU - Eriksson, U TI - Prevention of contrast media-associated nephropathy: randomized comparison of 2 hydration regimens in 1620 patients undergoing coronary angioplasty J2 - Arch Intern Med PY - 2002 VL - 162 SP - 329 EP - 336 UR - https://doi.org/10.1001/archinte.162.3.329 ER - TY - JOUR LB - 137. AU - Serruys, PW AU - Morice, MC AU - Kappetein, AP AU - Colombo, A AU - Holmes, DR AU - Mack, MJ TI - Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease J2 - N Engl J Med PY - 2009 VL - 360 SP - 961 EP - 972 UR - https://doi.org/10.1056/NEJMoa0804626 ER - TY - JOUR LB - 138. AU - Eriksen, BO AU - Ingebretsen, OC TI - The progression of chronic kidney disease: a 10-year population-based study of the effects of gender and age J2 - Kidney Int PY - 2006 VL - 69 SP - 375 EP - 382 UR - https://doi.org/10.1038/sj.ki.5000058 ER - TY - JOUR LB - 139. AU - Tajima, R AU - Kondo, M AU - Kai, H AU - Saito, C AU - Okada, M AU - Takahashi, H TI - Measurement of health-related quality of life in patients with chronic kidney disease in Japan with EuroQol (EQ-5D) J2 - Clin Exp Nephrol PY - 2010 VL - 14 SP - 340 EP - 348 UR - https://doi.org/10.1007/s10157-010-0304-1 ER - TY - JOUR LB - 140. AU - Kind, P AU - Dolan, P AU - Gudex, C AU - Williams, A TI - Variations in population health status: results from a United Kingdom national questionnaire survey J2 - BMJ PY - 1998 VL - 316 SP - 736 EP - 741 UR - https://doi.org/10.1136/bmj.316.7133.736 ER - TY - JOUR LB - 141. AU - Sullivan, PW AU - Slejko, JF AU - Sculpher, MJ AU - Ghushchyan, V TI - Catalogue of EQ-5D scores for the United Kingdom J2 - Med Decis Making PY - 2011 VL - 31 SP - 800 EP - 804 UR - https://doi.org/10.1177/0272989X11401031 ER - TY - GEN LB - 142. AU - Department of Health and Social Care TI - National Schedule of Reference Costs 2011–2012 CY - London PB - Department of Health and Social Care PY - 2012 UR - www.gov.uk/government/publications/nhs-reference-costs-financial-year-2011-to-2012 Y2 - 15 April 2019 ER - TY - BOOK LB - 143. AU - Curtis, L TI - Unit Costs of Health and Social Care 2012 CY - Canterbury PB - Personal Social Services Research Unit, University of Kent PY - 2012 ER - TY - GEN LB - 144. AU - Joint Formulary Committee TI - British National Formulary (BNF) ET - 62nd CY - London PB - British Medical Association and The Royal Pharmaceutical Society of Great Britain PY - 2013 ER - TY - GEN LB - 145. AU - National Institute for Health and Care Excellence (NICE) TI - Anaemia Management in People with Chronic Kidney Disease Clinical Guidelines, CG114 CY - London PB - NICE PY - 2011 UR - www.nice.org.uk/guidance/cg114 Y2 - 21 April 2020 ER - TY - JOUR LB - 146. AU - Solomon, R TI - The role of osmolality in the incidence of contrast-induced nephropathy: a systematic review of angiographic contrast media in high risk patients J2 - Kidney Int PY - 2005 VL - 68 SP - 2256 EP - 2263 UR - https://doi.org/10.1111/j.1523-1755.2005.00684.x ER - TY - JOUR LB - 147. AU - Nguyen, SA AU - Suranyi, P AU - Ravenel, JG AU - Randall, PK AU - Romano, PB AU - Strom, KA TI - Iso-osmolality versus low-osmolality iodinated contrast medium at intravenous contrast-enhanced CT: effect on kidney function J2 - Radiology PY - 2008 VL - 248.1 SP - 97 EP - 105 UR - https://doi.org/10.1148/radiol.2481071484 ER - TY - JOUR LB - 148. AU - Solomon, R AU - DuMouchel, W TI - Contrast media and nephropathy: findings from systematic analysis and Food and Drug Administration reports of adverse effects J2 - Invest Radiol PY - 2006 VL - 41.8 SP - 651 EP - 660 UR - https://doi.org/10.1097/01.rli.0000229742.54589.7b ER - TY - JOUR LB - 149. AU - From, AM AU - Bartholmai, BJ AU - Williams, AW AU - Cha, SS AU - McDonald, FS TI - Mortality associated with nephropathy after radiographic contrast exposure J2 - Mayo Clin Proc PY - 2008 VL - 83 SP - 1095 EP - 1100 UR - https://doi.org/10.4065/83.10.1095 ER - TY - JOUR LB - 150. AU - Klarenbach, SW AU - Pannu, N AU - Tonelli, MA AU - Manns, BJ TI - Cost-effectiveness of hemofiltration to prevent contrast nephropathy in patients with chronic kidney disease J2 - Crit Care Med PY - 2006 VL - 34 SP - 1044 EP - 1051 UR - https://doi.org/10.1097/01.CCM.0000206287.22318.C3 ER - TY - JOUR LB - 151. AU - Aguirre Caicedo, M TI - Nefropatía por medios de contraste J2 - Acta Med Colomb PY - 2007 VL - 32 SP - 68 EP - 79 ER -